TM 5-3805-254-20-1
GLOW PLUG - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
WARNING
Do not touch heater coil of glow plug when TESTING. Severe personal injury could occur.
4.
Glow plug (2)
Terminal (6), metal
Using jumper wire and 12 vdc power
housing (7), and
source, connect positive (+) wire to
heater coil (8)
terminal and negative (-) wire to metal
housing.
If heater coil turns red, glow plug is
good. If heater coil does not turn red,
replace glow plug.
INSTALLATION
5.
Pre-heater
Glow plug (2)
Screw in and tighten using 7/8-inch box-
housing (1)
end wrench.
6.
Glow plug (2)
Flat washer (5),
Screw on and tighten using 3/8-inch box-
wire (4), and
end wrench.
nut (3)
NOTE
FOLLOW-ON MAINTENANCE: Close left side hood panel (page 2-424).
TASK ENDS HERE
2-513