TM 5-3805-254-20-1
RADIATOR BYPASS COOLANT LINE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
WARNING
Dry-cleaning solvent P-D-680 is toxic and flammable. Wear protective safety goggles and gloves
and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and do not
breathe vapors. Do not use near open flame or excessive heat. The flashpoint for type #1 dry-
cleaning solvent is 100°F (38°C) and for type #2 is 138°F (59°C). If you become dizzy while using
cleaning solvent, get fresh air immediately, and get medical aid. If contact with eyes is made,
flush your eyes with water and get medical aid immediately.
11.
All metal parts
a.
Clean with dry-cleaning solvent.
b.
Using clean, dry rags, wipe dry.
INSPECTION/REPLACEM ENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-
424).
12.
Bypass pipe (8)
a.
Look for cracks, breaks, and holes.
and elbow (3)
b.
Look for damage to gasket surface.
2-649