TM 5-3805-254-20-2
BATTERY POSITIVE-TO-NEGATIVE CONNECTOR CABLE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
WARNING
Rubber apron, safety gloves, and safety goggles must be worn when working with
batteries. Failure to observe this precaution could cause serious injury to personnel.
Do not smoke, use open flame, or allow sparks near batteries. Mixture of oxygen and
hydrogen gases released from batteries is highly flammable and can explode causing
injury to personnel.
NOTE
Steps given are typical for both positive-to-negative connector cables.
1.
Two hooks (1)
Two latches (2)
Lift up and take off.
2.
Battery
Cover (4)
Lift up and take out.
compartment (3)
3.
Terminal (5)
Screw (6)
Using two 1/2-inch open-end wrenches,
and nut (7)
unscrew two turns.
4.
Post (8)
Terminal (5)
Using battery terminal puller, pull off.
5.
Terminal (9)
Screw (10)
Using two 1/2-inch open-end wrenches,
and nut (11)
unscrew two turns.
6.
Post (12)
Terminal (9)
Using battery terminal puller, pull off and
and cable (13)
take out.
DISASSEMBLY
NOTE
Steps given are typical for both positive-to-negative connector cables.
7.
Two terminals
Two screws (6
Using two 1/2-inch open-end wrenches,
(5 and 9)
and 10) and two
unscrew and take out.
nuts (7 and 11)
8.
Cable (13)
Two terminals (5
Using two 9/16-inch open-end wrenches,
and 9), two screws
unscrew and take out.
(14), and two nuts (15)
CLEANING
WARNING
Improper cleaning methods and use of unauthorized cleaning liquids or solvents can
injure personnel and cause damage to equipment. Refer to TM 9-247.
2-820