TM 5-3805-254-20-2
WET AIR RESERVOIR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
CAUTION
Care must be taken not to drop wet air reservoir. Damage to fittings or automatic drain valve could occur.
Antiseizing tape must be used on all pipe threads to provide a good seal and prevent threaded parts from
seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
38.
Two clamps (1)
Wet air
Put in place.
reservoir (2)
39.
Two screws (3) and
Screw in and tighten using two 9/16-inch
two new locknuts (4)
box-end wrenches.
40.
Wet air
90-degree elbow (5)
Wrap pipe threads with antiseizing tape.
reservoir (2)
41.
90-degree elbow (5)
Airhose to air
a.
Screw on and tighten using 1-inch open-
dryer (6)end wrench.
b.
Take off tag.
c.
Get rid of tag.
42.
Wet air
45-degree elbow (7)
Wrap pipe threads with antiseizing tape.
reservoir (2)
43.
45-degree elbow (7)
Airhose to dry air
a.
Screw on and tighten using 7/8-inch
reservoir rear (8)open-end wrench.
b.
Take off tag.
c.
Get rid of tag.
44.
Wet air
45-degree elbow (9)
Wrap pipe threads with antiseizing tape.
reservoir (2)
45.
45-degree elbow (9)
Airhose to dry air
a.
Screw on and tighten using 718-inch
reservoir front (10)open-end wrench.
b.
Take off tag.
c.
Get rid of tag.
46.
Wet air
Fitting (11)
Wrap pipe threads with antiseizing tape.
reservoir (2)
2-994