TM 5-3805-254-20-2
ALCOHOL EVAPORATOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective safety goggles and gloves and use
only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and do not breathe vapors. Do
not use near open flame or excessive heat. The flashpoint for type #1 drycleaning solvent is 100°F (38°C)
and for type #2 is 138°F (59°C). If you become dizzy while using cleaning solvent, get fresh air
immediately, and get medical aid. If contact with eyes is made, flush your eyes with water and get medical
aid immediately.
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-424).
11.
Housing (1)
Wipe clean using drycleaning solvent and
wiping rag.
12.
Cannister (2)
Wipe inside and outside clean using dry-
cleaning solvent and wiping rag.
INSPECTION/REPLACEMENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-
424).
13.
Housing (1)
a.
Look for cracks or breaks.
b.
Look for stripped or damaged elbow or
fitting hole threads.
c.
Look for damaged cannister screw
threads.
14.
Air tube (3)
a.
Look for cracks or breaks on sides.
b.
Look for clogged hole on end.
c.
Look for stripped or damaged threads.
2-998