TM 5-3805-254-20-2
ALCOHOL EVAPORATOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
ASSEMBLY
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
Position all elbows as shown in illustration.
17.
Housing (1)
Fitting (2)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 5/8-inch
open-end wrench.
18.
Fitting (2)
90-degree elbow (3)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 5/8-inch and
1/2-inch open-end wrenches.
19.
Housing (1)
90-degree elbow (4)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 1/2-inch
open-end wrench.
20.
Air tube (5) and new
Screw in and tighten using 7116-inch open-
rubber washer (6)
end wrench.
Do not overtighten.
21.
Fill cap (7)
Screw on.
TA244332