TM 5-3805-254-20-2
AIR COMPRESSOR GOVERNOR TO WET AIR RESERVOIR LINES AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
Air line is in three sections. See tags for correct locations.
16.
Wet air
Fitting (2)
Wrap pipe threads with antiseizing tape.
reservoir (1)
17.
Fitting (2), air
a.
Screw on and tighten using 11/16-inch
line (3), and
and 9/16-inch open-end wrenches.
line nut (4)
b.
Take off tag.
c.
Get rid of tag.
18.
Adapter (5)
Wrap pipe threads with antiseizing tape.
19.
Adapter (5)
Line nut (6)
Screw on and tighten using 11/16-inch and
9/16-inch open-end wrenches.
20.
Connector (7)
Wrap both male pipe threads with
antiseizing tape.
21.
Adapter (5)
Connector (7)
Screw on and tighten using 9/16-inch and
7/16-inch open-end wrenches.
22.
Connector (7)
Air line (8) and
a.
Screw on and tighten using 5/8-inch and
line nut (9)
9/16-inch open-end wrenches.
b.
Take off tag.
c.
Get rid of tag.
23.
Connector (10)
Wrap both male pipe threads with
antiseizing tape.
24.
Air line (8)
Connector (10) and
Screw on and tighten using 9/16-inch and
line nut (11)
7/16-inch open-end wrenches.
Change 1 2-1050