TM 5-3805-254-20-2
AIR COMPRESSOR GOVERNOR TO WET AIR RESERVOIR LINES AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
8.
Air line (1)
Line nut (2) and
a.
Using 9/16-inch and 7/16-inch open-
connector (3)
end wrenches, unscrew and take off.
b.
Take out air line.
9.
Adapter (4)
Connector (3)
Using 9/16-inch and 7/16-inch open-end
wrenches, unscrew and take off.
10.
Line nut (5)
Adapter (4)
Using 11/16-inch and 9/16-inch open-end
wrenches, unscrew and take off.
11.
Air line (6)
Tag.
12.
Wet air reservoir
Line nut (9) and
a.
Using 11/16-inch and 9/16-inch open-
(7)
fitting (8)
end wrenches, unscrew and take off.
b.
Take out air line (6).
CLEANING
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective safety goggles and gloves and use
only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and do not breathe vapors. Do
not use near open flame or excessive heat. The flashpoint for type #1 drycleaning solvent is 100°F (38°C)
and for type #2 is 138°F (59°C). If you become dizzy while using cleaning solvent, get fresh air
immediately, and get medical aid. If contact with eyes is made, flush your eyes with water and get medical
aid immediately.
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-424).
13.
All metal parts
Clean using drycleaning solvent and wiping
rag.
Change 1 2-1048