TM 5-3805-254-20-2
AIR COMPRESSOR GOVERNOR TO AIR DRYER LINES AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
Air line is in three sections. See tags for correct locations.
17.
Air dryer (1)
45-degree elbow (2)
Wrap pipe threads with antiseizing tape.
18.
45-degree elbow (2)
Air line (3)
a.
Screw on and tighten using 518-inch
and line nut (4)
open-end wrench.
b.
Take off tag.
c.
Get rid of tag.
19.
Clamp bracket (5)
Clamp (6), clamp
a.
Put clamp (6) around air line and posi-
and air line (3)
(7), screw (8), new
tion with clamp (7) on clamp bracket.
lockwasher (9), and
b.
Screw in and tighten using 7/16-inch
nut (10)
box-end and 7/16-inch open-end
wrenches.
20.
Adapter (11)
Wrap pipe threads with antiseizing tape.
21.
Adapter (11)
Line nut (12)
Screw on and tighten using 5/8-inch and
9/16-inch open-end wrenches.
22.
Connector (13)
Wrap both male pipe threads with
antiseizing tape.
23.
Connector (13)
Screw in and tighten using 9/16-inch and
7/16-inch open-end wrenches.
24.
Connector (13)
Air line (14) and
a.
Screw on and tighten using 5/8-inch and
line nut (15)
9/16-inch open-end wrenches.
b.
Take off tag.
c.
Get rid of tag.
25.
Connector (16)
Wrap both male pipe threads with
antiseizing tape.
26.
Air line (14)
Connector (16) and
Screw on and tighten using 9/16-inch and
line nut (17)
7/16-inch open-end wrenches.
27.
Connector (16)
Adapter (18)
Screw on and tighten using 9/16-inch and
7/16-inch open-end wrenches.
2-1044