TM 5-3805-254-20-2
DRY AIR RESERVOIR TO T-MANIFOLD HOSES - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
8.
T-manifold (1)
90-degree elbow (2)
Wrap pipe threads with antiseizing tape.
9.
90-degree elbow
Screw on and tighten using 1-inch open-end
(2) and airhose (3)
wrench.
10.
T-manifold (1)
90-degree elbow (4)
Wrap pipe threads with antiseizing tape.
11.
90-degree elbow
Screw on and tighten using 1-inch open-end
(4) and airhose (5)
wrench.
12.
Dry air
45-degree elbow (7)
Wrap pipe threads with antiseizing tape.
reservoir (6)
13.
45-degree elbow (7)
Airhose (5)
Screw on and tighten using 1-inch open-end
wrench.
14.
Dry air
90-degree elbow (8)
Wrap pipe threads with antiseizing tape.
reservoir (6)
15.
90-degree elbow (8)
Airhose (3)
Screw on and tighten using 1-inch open-end
wrench.
Change 1 2-1076