TM 5-3805-254-20-2
HORN RELAY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
CAUTION
Use care when working behind instrument panel pad to prevent breaking or disconnecting wires.
1.
Horn relay (1)
Three wires (2)
Pull off.
2.
Two screws (3), two
Using 7/16-inch box-end and 7/16-inch
lockwashers (4), and
open-end wrenches, unscrew and take out.
two nuts (5)
INSTALLATION
CAUTION
Use care when working behind instrument panel pad to prevent breaking or disconnecting wires.
3.
Firewall (6) and
Two screws (3), two
Screw in and tighten using 7/16-inch box-
horn relay (1)
new lockwashers (4),
end and open-end wrenches.
and two nuts (5)
4.
Three wires (2)
Push on.
TA244155
2-708