TM 5-3805-254-20-2
SECONDARY MAGNETIC SWITCH - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
4.
Firewall (11)
Secondary magnetic
Put in place and hold.
switch (1)
5.
Secondary magnetic
Two screws (8), two
Screw in and tighten using 7/16-inch box-
switch (1)
new lockwashers (9),
end and 7116-inch open-end wrenches.
and two nuts (10)
6.
Two new lockwashers
a. Put wires in place.
(7), four wires (6),
b. Screw on and tighten using 5/8-inch
and two nuts (5)
box-end wrench.
c. Get rid of tags.
7.
Two new lockwashers
a. Put wire in place.
(4), wire (3), and
b. Screw on and tighten using 11132-inch
nut (2)
box-end wrench.
c. Get rid of tags.
NOTE
FOLLOW-ON MAINTENANCE:
1.
Connect battery ground cable (page 2-424)
TA244153
2.
Install instrument panel pad (page 2-424)
2-705
3.
Close right cab door (page 2-424).
TASK ENDS HERE
TA244153
2-705