TM 5-3805-254-20-2
PRIMARY MAGNETIC SWITCH - CONTINUED
INITIAL SETUP - CONTINUED
Equipment Condition
Left side hood panel opened
(page 2-424).
Battery ground cable disconnected
(page 2-424).
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
1.
Primary magnetic
Two nuts (2), two
a. Tag wires (page 2-424).
switch (1)
lockwashers (3),
b. Using 3/8-inch box-end wrench, un-
and two wires (4)
screw and take out.
c. Get rid of lockwashers.
2.
Two nuts (5), two
a. Tag wires (page 2-424).
lockwashers (6), and
b. Using 1/2-inch box-end wrench, un-
three wires (7)
screw and take out.
c. Get rid of lockwashers.
3.
Two screws (8) and
a. Using number two cross-tip screw-
two lockwashers (9)
driver, unscrew and take out.
b. Get rid of lockwashers.
INSTALLATION
4.
Firewall (10)
Primary magnetic
Put in place and hold.
switch (1)
5.
Primary magnetic
Two screws (8) and
Screw in and tighten using number two
switch (1)
two new lock-
cross-tip screwdriver.
washers (9)
6.
Three wires (7),
a. Put wires in place.
two new lockwashers
b. Screw in and tighten using 112-inch
(6), and two nuts (5)
box-end wrench.
c. Get rid of tags.
2-702