TM 5-3805-254-20-2
VALVE-TO-CYLINDER PRESSURE HOSE AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
9. Clamp (11)
Two nuts (12) and
a. Using 7/16-inch box-end wrench, un-
CLEANING
WARNING
Improper cleaning methods and use of unauthorized cleaning liquids or solvents can injure personnel and
cause damage to equipment. Refer to TM 9-247.
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective safety goggles and gloves and use
only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and do not breathe vapors. Do
not use near open flame or excessive heat. The flashpoint for type #1 drycleaning solvent is 100°F
(380C) and for type #2 is 138°F (590C). If you become dizzy while using cleaning solvent, get fresh air
immediately, and get medical aid. If contact with eyes is made, flush your eyes with water and get medical
aid immediately.
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-424).
12
All metal parts
Using drycleaning solvent and cleaning
brush, clean thoroughly.
13
Two rubber hoses
Using liquid detergent, water, and cleaning
brush, clean thoroughly.
WARNING
Particles blown by compressed are hazardous Make certain the airstream is directed away from user and
other personnel in the area Compressed air used for cleaning purposes shall not exceed 30 psi (207 kPa)
User must wear safety goggles or face shield to prevent injury to personnel.
14
All parts
Using blow gun and air hose assembly,
blow dry.
2-1403