TM 5-3805-254-20-2
TRANSMISSION OIL PRESSURE GAGE LINE AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEMENT - CONTINUED
33
Lines (1)
Look for cracks, gouges, or worn line
covering.
34
Lines (1) and
Flare seats (3)
Look for cracks, bends, or dents.
fittings (2)
INSTALLATION
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts from
seizing.
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-424).
35
Straight pipe
Wrap pipe threads with antiseizing tape
fitting (3)
(page 2-424).
36
Torque converter
Straight pipe
Screw in and tighten using 7/16-inch open-
housing (4)
fitting (3)
end wrench.
TA244623
2-1458