TM 5-3805-254-20-2
AIR PRESSURE GAGE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEMENT - CONTINUED
7
Gage (1)
a
Look for cracks or dents.
b
Check to see if gage is readable.
8
Mounting bracket (2)
Look for cracks, bends, or breaks.
9
All threaded parts
Look for damaged threads or rounded
heads.
INSTALLATION
CAUTION
Use care when working behind upper center instrument panel to prevent breaking or disconnecting wires.
10
Gage (1)
Wrap pipe threads with antiseizing tape
(page 2-424).
11 Upper center instru-
Put in and hold.
ment panel (3)
Gage (1)
Position as shown.
12 Gage (1)
Mounting bracket (2)
Put on.
13
Two nuts (4)
Screw on and tighten using 9/16-inch open-
end wrench.
14
Screw on and tighten using 1/2-inch and
9/16-inch open-end wrenches.
15 Two adapters (5)
a
Screw on and tighten using 1/2-inch and
9/16-inch open-end wrenches
b
Get rid of tags.
16 Gage (1)
Light socket (7)
Push in.
2-1480