TM 5-3805-25434
13-4. TORQUE ROD REPLACEMENT (Cont).
b.
CLEANING AND INSPECTION
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear
protective goggles and gloves, and use only in a well-ventilated area. Avoid
contact with skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT
use near open flame or excessive heat. The solvent's flash point is 100°F-
138°F (380C-59°C). If you become dizzy while using cleaning solvent,
Immediately get fresh air and medical help. If solvent contacts eyes,
Immediately wash your eyes and get medical aid.
1.
Clean all parts with dry cleaning solvent.
2.
Inspect bushing (20) for damage. If damaged,
remove two retaining rings (18) and bushing
from torque rods (3 and 6).
3.
Inspect two lubrication fittings (19) for damage.
Replace lubrication fittings if damaged.
4.
Inspect torque rods (3 and 6) for damage.
Replace
if
damaged.
c.
INSTALLATION
1.
If removed, install two plates (14 and 15) an
brackets (4 and 16) on frame (8) with four screw
(13) and nuts (17). Torque nuts to 250-275 Ib.-
(339-373
Nm).
TA704096
13-22