TM 5-3805-254-34
17-2.
HYDRAULIC ROTARY PUMP MAINTENANCE (Cont).
6.
Separate housing (14) and bearing plate (21) from pump body (23).
7.
Remove two needle bearings (22) from pump body (23).
c. CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, Is toxic and flammable. Always wear protective goggles and
gloves, and use only In a well-ventilated area. Avoid contact with skin, eyes, and clothes, and DO
NOT breathe vapors. DO NOT use near open flame or excessive heat. The solvents flash point Is
100°F-138°F (38°C-59°C). If you become dizzy while using cleaning solvent, Immediately get fresh
air and medical help. If solvent contacts eyes, Immediately wash your eyes and get medical aid.
1.
Clean metal parts with dry cleaning solvent.
2.
Inspect metal parts for cracks, breaks, wear, and other damage. Replace if damaged.
3.
Inspect gearshafts for damaged or broken teeth. Replace if damaged.
4.
Inspect bearings (see TM 9-214). Replace if damaged.
5.
Apply thin coat of lubricating oil to all internal metal parts.
TA704234
17-7