TM 5-3805-264-13&P
OPERATOR MAINTENANCE
DUMP BODY TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
References
References (cont.)
TM 9-2320-302-10
TM 9-2320-363-10
TROUBLESHOOTING PROCEDURE
DUMP BODY
SYMPTOM
Dump body does not function properly.
MALFUNCTION
Dump body will not raise when hydraulic control lever is placed in up position.
CORRECTIVE ACTION
1.
Check position of main light switch.
Place main light switch in SER DRIVE or STOP LIGHT position (TM 9-2320-302-10
or TM 9-2320-363-10).
2.
Check if power take off (PTO) is engaged.
Engage PTO (TM 9-2320-302-10 or TM 9-2320-363-10).
CAUTION
To prevent overfilling hydraulic reservoir, DO NOT add hydraulic fluid when dump
body is raised. Failure to comply may result in damage to equipment.
3.
Check the hydraulic oil level in sight tube on reservoir.
4.
Check position of dump body transport lock.
Place transport lock in UNLOCKED position (WP 0004).
5.
Dump body still will not raise.
Notify Field Maintenance.
0009-1
03/15/2011Rel(1.10)root(tswp)wpno(T1002126413)