ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3. Set multimeter to 20 vdc scale. Connect red test lead to circuit breaker strip feed stud (3) and black test
lead to ground. Check for 11 to 13 vdc on multimeter. Disconnect test leads.
a. If multimeter does not read 11 to 13 vdc, go to step 4.
b. If multimeter reads 11 to 13 vdc, go to step 15.