ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e. If 8 wire (1) is not loose, corroded, frayed, or broken, go to step 5.
Step 5. Set multimeter to ohms scale and adjust to 0 ohms. Connect red test lead to circuit breaker terminal feed
stud (2) and black test lead to terminal (5) on secondary magnetic switch (6). Check for 0 ohms on
multimeter. Disconnect test leads.
a. If multimeter reads no continuity, 8 wire (1) must be replaced. Notify Direct Support
Maintenance.
b. If multimeter reads 0 ohms, connect batteries (page 2-424) and go to step 6.
2-171