TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 21.
Test 51 wire (8) as follows: Disconnect batteries (page 2-424). Pull wire connector (6) off
LIGHTS switch (3). Set multimeter to ohms scale and adjust to 0 ohms. Connect red test lead
to wire connector (6) and black test lead to 51 wire (8) on wire connector (9). Check for 0 ohms
on multimeter. Disconnect test leads.
a.
If multimeter reads no continuity, 51 wire (8) must be replaced. Notify Direct Support
Maintenance.
b.
If multimeter reads 0 ohms, push wire connector (6) on to terminal (10) on LIGHTS switch (3).
Close upper instrument panel (page 2-424). Go to step 22.
2-185