TM 5-3805-254-20-2
AUXILIARY TRANSMISSION - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
FILLING
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
4.
Auxiliary
Drainplug (2)
a.
Wipe clean using wiping rag.
transmission (1)
b.
Wrap pipe threads with antiseizing tape.
c.
Screw in and tighten using 112-inch
square key.
5.
Auxiliary
Using lubricating bucket pump, fill through
transmission (1)
filler plug hole until oil comes out
(LO 5-3805-254-12).
6.
Filler plug (3)
a.
Wipe clean using wip ing rag.
b.
Wrap threads with antiseizing tape.
c.
Screw in and tighten using 15/16-inch
open-end wrench.
TASK ENDS HERE
TA244292
2-934