TM 5-3805-254-20-2
WET AIR RESERVOIR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DISASSEMBLY
8.
Wet air
90-degree elbow (2)
Using 13/16-inch open-end wrench, un-
reservoir (1)
and 45-degree elbows
screw and take out.
(3 and 4)
9.
Fitting (5)
Fitting (6)
Using 11/16-inch and 9/16-inch open-end
wrenches, unscrew and take out.
10.
Fitting (7)
Fitting (5)
Using 7/8-inch and 11/16-inch open-end
wrenches, unscrew and take out.
11.
Wet air
Fitting (7)
Using 7/8-inch open-end wrench, unscrew
reservoir (1)
and take out.
12.
Fitting (8)
Automatic drain
Using 1 1/8-inch and 11/16-inch open-end
valve (9)
wrenches, unscrew and take out.
13.
Tee fitting (10)
Fitting (8)
Using 314-inch and 11/16-inch open-end
wrenches, unscrew and take out.
14.
Plug (11)
Using 3/8-inch open-end wrench, unscrew
and take out.
15.
Fitting (12)
T-fitting (10)
Using two 3/4-inch open-end wrenches,
unscrew and take off.
16.
Wet air
Fitting (12)
Using 3/4-inch open-end wrench, unscrew
reservoir (1)
and take out.
17.
Fitting (13)
Pressure relief
Using 7/8-inch and 5/8-inch open-end
valve (14)
wrenches, unscrew and take out.
18.
Wet air
Fitting (13)
Using 7/8-inch open-end wrench, unscrew
reservoir (1)
and take out.
CLEANING
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective safety goggles and gloves and use
only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and do not breathe vapors. Do
not use near open flame or excessive heat. The flashpoint for type #1 drycleaning solvent is 100°F (38°C)
and for type #2 is 138°F (59°C). If you become dizzy while using cleaning solvent, get fresh air
immediately, and get medical aid. If contact with eyes is made, flush your eyes with water and get medical
aid immediately.
2-988