TM 5-3805-254-20-2
DRY AIR RESERVOIR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
WARNING
Due to excessive weight and size, assistance will be needed when handling dry air reservoir. Failure to
observe this precaution could cause injury to personnel.
CAUTION
Care must be taken not to drop dry air reservoir. Damage to fittings or draincocks could occur.
43.
Bracket (1)
Dry air
With assistance, put on.
reservoir (2)
44.
Two cable
Put over dry air reservoir (2) and through
assemblies (3)
bracket.
45.
Two cable
Two nuts (4), two
Screw on and tighten using 9/16-inch, 112-
assemblies (3)
new lockwashers (5),
inch drive deep socket, 6inch extension,
and two flat
and ratchet handle.
washers (6)
46.
Dry air
90-degree elbow (7)
Wrap pipe threads with antiseizing tape.
reservoir (2)
47.
90-degree elbow (7)
Airhose to wet air
a.
Screw on and tighten using 7/8-inch
reservoir rear (8)open-end wrench.
b.
Take off tag.
c.
Get rid of tag.
48.
Dry air
90-degree elbow (9)
Wrap pipe threads with antiseizing tape.
reservoir (2)
49.
90-degree elbow (9)
Airhose to wet air
a.
Screw on and tighten using 7/8-inch
reservoir front (10)
open-end wrench.
b.
Take off tag.
c.
Get rid of tag.
50.
Dry air
90-degree elbow (11)
Wrap pipe threads with antiseizing tape.
reservoir (2)
51.
90-degree elbow (11)
Airhose to relay
a.
Screw on and tighten using 1 1/4-inch
valve (12)
open-end wrench.
b.
Take off tag.
c.
Get rid of tag.
2-984