TM 5-3805-254-20-2
DRY AIR RESERVOIR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
ASSEMBLY
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
Position all elbows as shown in illustration.
29.
Dry air
45-degree elbow (2)
a.
Wrap pipe threads with antiseizing tape.
reservoir (1)
b.
Screw in and tighten using 1-inch open-
end wrench.
30.
45-degree elbow (2)
Check valve (3)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 1 318-inch
open-end wrench.
31.
Check valve (3)
90-degree elbow (4)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 1 3/8-inch
and 13/16-inch open-end wrenches.
32.
Dry air
45-degree elbow (5)
a.
Wrap pipe threads with antiseizing tape.
reservoir (1)
b.
Screw in and tighten using 1-inch open-
end wrench.
33.
45-degree elbow (5)
Check valve (6)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 1 3/8-inch
open-end wrench.
34.
Check valve (6)
90-degree elbow (7)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 1 3/8-inch
and 13/16-inch open-end wrenches.
35.
Dry air
90-degree elbow (8)
a.
Wrap pipe threads with antiseizing tape.
reservoir (1)
b.
Screw in and tighten using 7/8-inch
open-end wrench.
36.
45-degree elbow (9)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 3/4-inch
open-end wrench.
37.
90-degree elbow (10)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 13/16-inch
open-end wrench.
2-982