TM 5-3805-254-20-2
DRY AIR RESERVOIR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
NOTE
Steps 38 and 39 are typical for both draincocks.
38.
90-degree elbow (11)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 11/16-inch
open-end wrench.
Position facing rear of dry air
reservoir.
39.
90-degree elbow (11)
Draincock (12)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 9/16-inch
open-end wrench.
c.
Turn to close.
40.
Dry air
Five plugs (13)
a.
Wrap pipe threads with antiseizing tape.
reservoir (1)
b.
Screw in and tighten using 38-inch,
1/2-inch drive square socket and
ratchet handle.
41.
Four step studs (14)
Step (15)
Put on.
42.
Four new locknuts
Screw on and tighten using 9/16-inch box-
(16) and four flat
end wrench.
washers (17)
TA244322
2-983