TM 5-3805-254-20-2
AIR DRYER - CONTINUEDTM 5-3805254-20-2
ACTION
LOCATION
ITEM
REMARKS
ASSEMBLY
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
Position all elbows as shown in illustration.
32.
Head assembly (7)
45-degree elbow (10)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 5/8-inch
open-end wrench.
33.
Air dryer (1)
90-degree elbow (11)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 13116-inch
open-end wrench.
34.
90-degree elbow (11)
Pressure relief
a.
Wrap pipe threads with antiseizing tape.
valve (12)
b.
Screw in and tighten using 3/4-inch
open-end wrench.
35.
Airdryer (1)
Two plugs (13)
a.
Wrap pipe threads with antiseizing tape.
b.
Screw in and tighten using 7/8-inch
box-end wrench.
TA244339
2-1009