TM 5-3805-254-20-2
FRONT REAR QUICK RELEASE VALVE TO PARKING AIRBRAKE CHAMBER HOSES - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
See tags for correct location of airhoses.
11.
Left parking air-
Fitting (2)
Wrap pipe threads with antiseizing tape.
brake chamber (1)
12.
Fitting (2) and left
Screw on and tighten using 3/4-inch and
airhose (3)
5/8-inch open-end wrenches.
13.
Right parking air-
Fitting (5)
Wrap pipe threads with antiseizing tape.
brake chamber (4)
14.
Fitting (5) and
Screw on and tighten using 3/4-inch and
right airhose (6)
5/8-inch open-end wrenches.
15.
Front rear quick
45-degree elbow (8)
Wrap pipe threads with antiseizing tape.
release valve (7)
16.
45-degree elbow (8)
a.
Screw on and tighten using 3/4-inch
and right airhose (6)
open-end wrench.
b.
Take off tag.
c.
Get rid of tag.
17.
Fitting (9)
Wrap pipe threads with antiseizing tape.
18.
Fitting (9) and left
a.
Screw on and tighten using 314-inch and
airhose (3)
11/16-inch open-end wrenches.
b.
Take off tag.
c.
Get rid of tag.