TM 5-3805-254-20-2
FRONT RELAY VALVE TO REAR RELAY VALVE HOSE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
8.
Rear relay
45-degree elbow (2)
Wrap pipe threads with antiseizing tape.
valve (1)
9.
45-degree elbow (2)
Screw on and tighten using 1 1/4-inch
and line nut (3)
open-end wrench.
10.
Front relay
45-degree elbow (5)
Wrap pipe threads with antiseizing tape.
valve (4)
11.
45-degree elbow (5)
Screw on and tighten using 1 1/4-inch
and line nut (6)
open-end wrench.
NOTE
Steps 12 and 13 are typical for two clamp assemblies.
12.
Airhose (7)
Clamp (8)
Put on.
13.
Clamp bracket (9)
Clamp (8), screw
a.
Aline holes in clamp and clamp bracket.
(10), new lock-
b.
Screw in and tighten using 7/16-inch
washer (11), and
box-end and 7/16-inch open-end
nut (12)
wrenches.
TASK ENDS HERE
TA244395
Change 1 2-1104