TM 5-3805-254-20-2
FRONT RELAY VALVE T-FITTING TO REAR RELAY VALVE HOSE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
6.
Airhose (8)
a.
Check for cracks, breaks, chafing, or
hardness.
b.
Look for excessive rust or corrosion.
7.
All threaded parts
Look for damaged threads or rounded
heads.
INSTALLATION
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
8.
Rear relay valve (9)
90-degree elbow (1)
Wrap pipe threads with antiseizing tape.
9.
90-degree elbow (1)
90-degree elbow (1)
Screw on and tighten using 7/8-inch open-
and line nut (2)
end wrench.
10.
Front relay
Front relay valve T-fitting
Wrap pipe threads with antiseizing tape.
valve (10)
(11) and fitting (11.1)
11.
Front relay valve T-fitting
Screw on and tighten using 718-inch and
(11), fitting (11.1), and line
3/4-inch open-end wrenches.
nut (12)
Change 1 2-1107