TM 5-3805-254-20-2
CAB FLOOR THROUGH CONNECTOR TO DOUBLE CHECK VALVE HOSE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
8.
Under cab floor (16)
Cab floor through-
Using 9/16-inch open-end wrench, un-
connector 45-degree
screw and take off.
elbow (17)
NOTE
Assistance will be needed when performing step 9.
9.
Top of cab floor
Anchor coupling
Using 1 1/8-inch and 1-inch open-end
(18) and under cab
(19), flat washer
wrenches, unscrew and take out.
floor (16)
(20), and nut (21)
TA244401
2-1111