TM 5-3805-254-20-2
CAB FLOOR THROUGH CONNECTOR TO DOUBLE CHECK VALVE HOSE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
WARNING
Safety gogles must be worn when working under truck to prevent eye injury.
20.
Anchor coupling (1)
Cab floor through-
a.
Wrap both male pipe threads with anti-
connector 45-degree
seizing tape.
elbow (2)
b.
Screw in and tighten using 9/16-inch
open-end wrench.
Position to face left side cab door.
21.
Cab floor through
Airhose (3)
Screw on and tighten using 3/4-inch open-
connector 45-degree
end wrench.
elbow (2)
22.
Double check
90-degree elbow (5)
Wrap pipe threads with antiseizing tape.
valve (4)
23.
90-degree elbow
Screw on and tighten using 3/4-inch open-
(5) and airhose (3)
end wrench.
NOTE
Steps 24 and 25 are typical for three clamp assemblies.
24.
Airhose (3)
Clamp (6)
Put on.
25.
Clamp bracket (7)
Clamp (6), screw
a.
Aline holes in clamp and clamp bracket.
(8), new lockwasher
b.
Screw in and tighten using 7/16-inch
(9), and nut (10)
box-end and 7/16-inch open-end
wrenches.
Change 1 2-1114