TM 5-3805-254-20-2
RESERVOIR-TO-PUMP HOSE AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Particles blown by compressed air are hazardous. Make certain the air stream is directed away from user and
other personnel in the area Compressed air used for cleaning purposes shall not exceed 30 psi (207 kPa) User
must wear safety goggles or face shield to prevent injury to personnel.
6
Elbow (1) and
Using air blow gun and air hose assembly,
hose (2)
blow dry.
INSPECTIONIREPLACEMENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions
(page 2-424).
7
Elbow (1)
Look for bends, dents, or cracks.
8
Hose (2)
Look for worn areas or gouges.
9
All threaded parts
Look for damaged threads or rounded
heads.
INSTALLATION
10
Elbow (3)
Hose (2)
Screw on and tighten using two 1 1/2-inch
open-end wrenches.
11
Reservoir (4)
Elbow (1)
a
Wrap pipe threads with antiseizing tape
(page 2-424).
b
Screw in and tighten using 1 5/16-inch
open-end wrench.
12
Elbow (1)
Hose (2)
Screw on and tighten using 1 1/2-inch and
1 5/16-inch open-end wrenches.
13
Reservoir (4)
Drainplug (5)
a
Wrap pipe threads with antiseizing tape
(page 2-424).
b
Screw in and tighten using 7/16-inch
open-end wrench.
2-1226