TM 5-3805-254-20-2
PUMP-TO-VALVE PRESSURE HOSE AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEMENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-424).
9.
Two elbows (1 and 2)
Look for cracks, bends, or dents.
and bushing (3)
10.
Hose (4)
Look for cracks, gouges, or worn areas.
11.
All threaded parts
Look for damaged threads or rounded
heads.
INSTALLATION
12. Valve (5)
Bushing (3)
a. Wrap pipe threads with antiseizing tape
(page 2-424).
b. Screw in and tighten using 1 3/8-inch
open-end wrench.
13. Bushing (3)
Elbow (1)
a. Wrap pipe threads with antiseizing tape
(page 2-424).
b. Screw in and tighten using 1 1/4-inch
and 1 3/8-inch open-end wrenches.
14. Elbow (1)
Hose (4)
Screw in and tighten using two 1 114-inch
open-end wrenches.
15. Pump (6)
Elbow (2)
a. Wrap pipe threads with antiseizing tape
(page 2-424).
b. Screw in and tighten using two 1 114-
inch open-end wrenches.
16. Elbow (2)
Hose (4)
Screw in and tighten using two 1 1/4-inch
open-end wrenches.
17. Dump body (7)
Lower completely (page 2-424).
18. Reservoir (8)
Cap (9)
Turn counterclockwise and take off.
19. Filler neck (10)
Fill with lubricating oil until sight glass (11)
is full.
2-1388