TM 5-3805-254-34
5-1.
GENERATOR REPAIR (Cont).
12. Loosen two Insulated screws (21) and brush holder
(22) from end (1).
13. Remove nut (23), screw (28), and wire (25).
14. Remove nut (24) and bracket (26) from end (1).
15. Remove nut (27) and bracket (29) from end (1).
16. Connect multimeter to heat sink (31) and one flat
metal chip (32). Press firmly on flat metal chip and
record reading. Reverse lead connections and
record reading. If both readings are the same,
replace rectifier bridge (30). Repeat step for other
heat sink and flat metal chips.
TA703697
5-4