TM 5-3805-254-34
5-1.
GENERATOR REPAIR (Cont).
17. Remove three screws (34) and rectifier bridge (30)
from end (1).
18. Remove screw (35) and capacitor (33) from end (1).
19. Set multimeter on lowest range scale and connect
one lead to brush lead clip (36) and one lead to end
(1). Record reading. Reverse lead connections and
record reading. If both readings are zero, either
brush lead clip is grounded or regulator (37) is
defective.
TA703698
5-5