Figure 10. MCS Tailgate.
Figure 12. MCS Tailgate Components.

Parts Manual For Truck, Dump, Heavy, Body M917A1 And M917A2
Page Navigation
  91    92    93    94    95  96  97    98    99    100    101  
img
.
TM 5-3805-264-13&P
0017
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
Figure 11. MCS Control Unit.
WARNING
When connected, MCS remote control
overrides cab control unit. When remote
control is disconnected, cab control
activates. To avoid inadvertent opening or
closing of gates, ALWAYS check gate
positions and position of toggle switches on
both cab and remote controls before
plugging in or unplugging remote control.
Toggle switches should be in CLOSED
position. Failure to comply may result in
personnel injury or death.
MCS remote control does
3. Plug MCS remote control (Figure 12, Item 6) into
not work and is required
receptacle (Figure 12, Item 7) at either side of MCS
for mission.
tailgate (Figure 12, Item 1). Check that appropriate
0017-11