TM 5-3805-254-20-1
FUEL PUMP FUEL FILTER - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
4.
Filter cap (2),
Clean thoroughly with drycleaning solvent.
spring (4), and
magnetic filter (5)
WARNING
Particles blown by compressed air are hazardous. Make certain the airstream is directed away
from user and other personnel in the area. Compressed air used for cleaning purposes shall not
exceed 30 psi (207 kPa). User must wear safety goggles or face shield to prevent injury to
personnel.
5.
Filter cap (2),
Using air hose assembly and air blow gun,
spring (4), and
dry thoroughly.
magnetic filter (5)
INSPECTION/REPLACEM ENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-
424).
6.
Filter cap (2),
Look for cracks, breaks, and gouged or
spring (4), and
stripped threads.
magnetic filter (5)
2-479