TM 5-3805-254-20-1
HAND THROTTLE CONTROL - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
CAUTION
Use care when installing grommet as damage to temperature gage tube and wires could occur.
16.
Firewall (1)
New grommet (2),
a.
Open grommet and put in wire and tube.
wire (3), and
b.
Put grommet in place using 3/16-inch
tube (4)
flat-tip screwdriver.
CAUTION
Use care when installing hand throttle cable as damage to wiring could occur.
17.
Dashboard (5)
Hand throttle cable
a.
Put hand throttle cable in place.
(6), new lockwasher
b.
Screw on nut and lockwasher.
(7), and nut (8)
c.
Tighten nut using 9/16-inch open-end
wrench.
18.
Drivers side
Hand throttle
Push through hole.
firewall (9)
cable (6)
TA244082
2-586