TM -3805-254-20-1
EXHAUST DIVERTER - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Dry-cleaning solvent P-D-680 is toxic and flammable. Wear protective safety goggles and gloves
and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and do not
breathe vapors. Do not use near open flame or excessive heat. The flashpoint for type #1
drycleaning solvent is 100°F (38°C) and for type #2 is 138°F (59°C). If you become dizzy while
using cleaning solvent, get fresh air immediately, and get medical aid. If contact with eyes is
made, flush your eyes with water and get medical aid immediately.
Safety goggles must be worn when using wire brush. Flying rust and metal particles could cause
eye injury.
6.
All parts
a.
Using wire brush, remove any rust.
b.
Clean in dry-cleaning solvent.
c.
Using clean dry rags, wipe dry.
INSPECTION/REPLACEMENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-
424).
7.
Exhaust diverter (1)
a.
Look for cracks, holes, broken welds,
and severe rust.
b.
Check flapper valve (2) for proper
operation.
c.
Check for weak or broken springs.
8.
All threaded parts
Look for damaged threads or rounded
heads.
INSTALLATION
WARNING
Edges of exhaust system components are sharp. Care must be taken to prevent personal injury.
9.
Muffler(3)
Exhaust diverter (1)
Put in far enough to hold securely.
10.
Bracket (4)
Two screws (5) and
a.
Put in position.
two nuts (6)
b.
Screw in and tighten using two 3/4-inch
box-end wrenches.
2-602