TM 5-3805-254-20-2
AIR HORN CONTROL VALVE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-424).
13
Air horn control
a
Clean with solution of liquid detergent
valve (1), two elbow
and water.
fittings (2 and 3),
b
Rinse in clean water.
locknut (4), and tee
c
Using clean wiping rags, wipe dry.
fitting (5)
INSPECTION/REPLACEMENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-424).
14
Air horn control
Look for cracks, breaks, and damaged
valve (1)
threads.
15
Two elbow fittings
Look for cracks, breaks, and damaged
(2 and 3), locknut
threads.
(4), and tee
fitting (5)
ASSEMBLY
NOTE
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
For more information on how to use antiseizing tape, go to General Maintenance Instructions.
2-1358