HYDRAULIC OIL RESERVOIR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING - CONTINUED
WARNING
Particles blown by compressed air are hazardous. Make certain the air stream is directed away from user
and other personnel in the area. Compressed air used for cleaning purposes shall not exceed 30 psi (207
kPa). User must wear safety goggles or face shield to prevent injury to personnel.
25.
All parts
Using air blow gun and air hose assembly,
blow dry.
INSPECTION/REPLACEMENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-424).
26.
Reservoir (1)
a. Look for holes or large dents.
b. Look for cracks in welded areas.
c. Look for pitted areas inside.
27.
Sight glass (2)
a. Look for cracks.
b. Check for clearness of glass.
28.
Cap (3)
a. Look for dents or cracks.
b. Look for clogged vent holes.
29.
All threaded parts
Look for damaged threads or rounded
heads.
ASSEMBLY
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
2-1380