TM 5-3805-254-34
6-15.
OIL PUMP, FRONT SUPPORT, AND CONVERTER HOUSING REPLACEMENT (Cont).
12. Remove three bolts (19), 16 bolts (20), front support
(15), and gasket (21) from converter housing (5).
Discard gasket.
b.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, Is toxic
and
flammable.
Always
wear
protective goggles and gloves, and
use only In a well-ventilated area.
Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors.
DO NOT use near open flame or
excessive heat. The solvents flash
point is 100°F-138°F (38°C-59°C). If
you
become
dizzy
while
using
cleaning solvent, Immediately get
fresh air and medical help if solvent
contacts eyes, Immediately wash
your eyes and get medical aid.
1.
Clean converter housing with dry cleaning solvent.
2.
Inspect converter housing
for
cracks,
breaks,
distortion, or other damage. Replace if damaged.
c.
INSTALLATION
1.
Place front of converter housing (5) on work surface
facing downward.
2.
Position new gasket (21) on converter housing (5)
with holes in gasket alined with holes of converter
housing.
3.
Install front support (15) with three bolts (19).
Torque bolts to 36-43 lb.-ft (49-58 Nm).
4.
Install one of 16 bolts (20) into hole between two valve bores In front support (15) that are closer to each other.
Torque bolts to 36-43 Ib.-ft. (49-58 Nm).
5.
Install remaining 15 bolts (20) into outer bolt circle of front support (I 15). Torque bolts to 36-43 Ib.-ft. (49-58 Nm).
TA703810
6-89