TM 5-3805-264-14&P
4-71.
HYDRAULIC CONTROL LEVER CABLE REPLACEMENT (Con't).
10.
Install spacer (33), hydraulic control lever cable (36), clamp (32), two screws (34), new lockwashers (30),
and nuts (31) to bracket (35).
11.
Place hydraulic control lever in DOWN position (paragraph 2-1).
12.
By hand, push end of cable (36) in as far as it will go and install pivot pin (28) in same hole in bracket (27)
as removed. If this cannot be achieved, perform step 14.
13.
Release hand pressure from cable (36). Force of hydraulic pump actuator will cause hydraulic control lever
to N (Neutral) position.
14.
Loosen nut at pivot pin (28) and rotate pivot pin in desired direction. Tighten nut.
15.
Repeat steps 12 thru 14 until pivot pin (28) can be installed in same hole in bracket (27) as removed with
cable (36) pushed in all the way. Install retaining pin (29).
4-129