HYDRAULIC CONTROL LEVER CABLE REPLACEMENT (Con't).
4.
5.
Tag and disconnect shift tower jumper harness power and ground connectors (13) from cab harness
power and ground connectors (12).
Remove grommet (11) and cab harness power and ground connectors (12) from shift tower (1).
NOTE
6.
7.
8.
9.
To ease installation, note mounting position of cable pivot pins and hold-down
clamps prior to disconnecting cables.
Place transmission selector lever in D (Down) position (TM 9-2320-363-10).
Tag transmission shift cable (15).
Remove two nuts (10), lockwashers (9), screws (6), clamp (8), and spacer (7) from bracket (14). Discard
lockwashers.
Remove retaining pin (4) from pivot pin (5) and pivot pin from bracket (16).