TM 5-3805-264-14&P
4-72.
HYDRAULIC HOSES AND FITTINGS REPLACEMENT (Con't).
NOTE
5.
6.
7.
Perform steps 5 thru 7 to install suction hose.
Install elbow (17) and hose barb (16) to bottom of hydraulic reservoir (4).
Install adapter (13) to hydraulic pump (12).
Install suction hose (15) and two clamps (14) to adapter (13) and hose barb (16). Tighten clamps
NOTE
8.
9.
10.
11.
Perform steps 8 thru 11 to install return hose and fittings.
Install tee (2) on filter housing (3).
Install oil sampling valve (1) on tee (2).
Install adapter (18) to hydraulic pump (12).
Install return hose (19) to adapter (18) and tee (2).
FOLLOW-ON TASKS:
Install transmission tunnel access cover (TM 9-2320-363-20)
Fill hydraulic reservoir (Chapter 3, Section I).