TM 5-3805-254-20-2
HEADLIGHT ASSEMBLY - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
NOTE
The purpose of steps 25, 26, and 27 is to make sure that both left and right headlights are
equally 25 feet (7.6 meters) from wall or screen.
Assistance will be needed to perform this task.
25.
Level area
Floor (11)
a.
Using chalk, make mark (12) where wall
and wall (10)
meets floor.
b.
Using 50-foot tape measure and chalk,
measure 6 feet 5 1/2 inches (1.97 m) to
left of mark (12) and make mark (13)
where wall meets floor.
c.
Using carpenters square, 50-foot tape
measure and chalk, measure straight
out from mark (13) 27 feet 11 1/2 inches
(8.52 m) on floor and draw line (14).
d.
Make mark (15) at end of line (14).
e.
Using carpenters square, 50-foot tape
measure and chalk, measure straight
out from mark (12) 27 feet 11 1/2 inches
(8.52 m) on floor and draw line (16).
f.
Make mark (17) at end of line (16).
g.
Using 50-foot tape measure and chalk,
draw line (18) between mark (15) and
mark (17) and extend line (18) 3 feet
(.91 m) at both ends.
TA244212
2-813