TM 5-3805-254-20-2
HYDRAULIC FILTER AND HOUSING - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
WARNING
Improper cleaning methods and use of unauthorized cleaning liquids or solvents can injure personnel and
cause damage to equipment. Refer to TM 9-247.
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective safety goggles and gloves and use
only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and do not breathe vapors. Do
not use near open flame or excessive heat. The flashpoint for type #1 drycleaning solvent is 1000F
(380C) and for type #2 is 138°F (590C). If you become dizzy while using cleaning solvent, get fresh air
immediately, and get medical aid. If contact with eyes is made, flush your eyes with water and get medical
aid immediately.
NOTE
All parts must be cleaned thoroughly.
For more information on how to clean parts, go to General Maintenance Instructions (page 2-424).
6
All parts
Using drycleaning solvent, clean
thoroughly.
WARNING
Particles blown by compressed air are hazardous. Make certain the airstream is directed away from user
and other personnel in the area. Compressed air used for cleaning purposes shall not exceed 30 psi (207
kPa). User must wear safety goggles or face shield to prevent injury to personnel.
7
All parts
Using air blow gun and air hose assembly,
blow dry.
INSPECTION/REPLACEM ENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-424).
2-1364