TM 5-3805-254-20-2
HYDRAULIC FILTER AND HOUSING - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION - CONTINUED
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
13 Filter housing (1)
Drainplug (2)
a. Wrap pipe threads with antiseizing tape.
b. Screw in and tighten using 7/16-inch
open-end wrench.
14. Reservoir (3)
Cap (4)
Take off.
15
Filler neck (5)
Fill with lubricating oil
(LO 5-3805-254-12).
16. Suction hose (6)
Valve (7)
Turn counterclockwise to open.
TA244564
TASK ENDS HERE
2-1366